Compressed Air Dew Point Converter (PDP ↔ ADP) #
Convert compressed air pressure dew point (PDP) to atmospheric dew point (ADP) and back. Uses a Magnus vapor-pressure approximation at line pressure—not an HVAC room psychrometric calculator. Next: size the dryer with the air dryer sizing calculator.
Conversion Inputs
Advanced calculator
Absolute pressure = gauge + atmospheric. Default sea-level atmosphere ≈ 1.01325 bar.
About this calculator
Engineering approximation: e_s from Magnus at the known dew point, then e₂ = e₁ × (P₂ / P₁) with constant mole fraction, then invert for the other dew point. ISO 8573-1 water class uses pressure dew point. For dryer rated SCFM, open the air dryer sizing calculator. Browse all pneumatic air treatment tools.
Results
Continue Your Calculation
After converting PDP and ADP, size the dryer for your target pressure dew point.
Quick Reference: PDP vs ISO Water Class #
| ISO 8573-1 water | Max PDP | Typical dryer |
|---|---|---|
| Class 4 | ≤ +3°C | Refrigerated |
| Class 3 | ≤ −20°C | Desiccant |
| Class 2 | ≤ −40°C | Desiccant |
| Class 1 | ≤ −70°C | Desiccant (deep dry) |
Formulas and Method #
Magnus saturation vapor pressure
e_s(T) = 6.112 × exp(17.62·T / (243.12 + T)) [hPa, T in °C]
Pressure scaling (engineering approximation)
e_atm = e_p × (P_atm / P_abs) ; P_abs = P_gauge + P_atm
Invert Magnus to recover the other dew point. Accuracy depends on ideal-gas assumptions and how closely mole fraction is conserved.
Assumptions and Limitations
Planning estimate only. Gauge vs absolute pressure must be consistent. Not for instrument calibration, and not for HVAC psychrometric processes (use the psychrometric calculator for room air).
Worked example #
PDP +3°C @ 7 bar(g) (P_abs ≈ 8.013 bar, sea level) → ADP ≈ −23°C. Reverse the same inputs to close the loop near +3°C PDP. Then size a refrigerated dryer for Class 4 water with the dryer sizing calculator.
Frequently Asked Questions #
How do I convert pressure dew point to atmospheric dew point?
Compute saturation vapor pressure at the PDP with Magnus, scale by P_atm / P_abs, then invert for ADP. At +3°C PDP and 7 bar(g), ADP is about −23°C with this approximation.
What is the difference between PDP and ADP for compressed air?
PDP is condensation temperature under line pressure (what dryer and ISO specs use). ADP is the dew point of the same moisture content expanded to atmosphere—useful for comparing sensors or charts, not for replacing PDP in dryer specs.
Is this the same as an HVAC dew point calculator?
No. This page is for compressed-air pressure dew point at working pressure. HVAC psychrometrics solve moist air at near-atmospheric conditions for rooms and ducts.
Related Tools
Related Guides
- Refrigerated vs Desiccant Air Dryer — PDP targets and dryer sizing steps
- Compressed Air System Efficiency Guide — Moisture and energy context