How to Use Solar Irradiance Data for PV Design
Introduction #
How to use solar irradiance data for PV design: convert resource maps or site measurements into peak sun hours (PSH) or daily insolation (kWh/m²/day), then feed array sizing and production tools. Irradiance (W/m²) is instantaneous intensity; design usually needs energy over a day. Use the Peak Sun Hours Calculator to convert climate bands or W/m² × daylight hours into planning PSH.
Best for: engineers turning weather/resource files into sizing inputs.
Not ideal for: replacing TMY weather-year simulations (PVsyst/SAM) or satellite API products.
Irradiance vs insolation vs PSH #
Conclusion: W/m² is power density; kWh/m²/day and PSH are energy metrics for sizing.
| Term | Unit | Use |
|---|---|---|
| Irradiance | W/m² | Instant intensity (sensor / clear-sky) |
| Insolation / irradiation | kWh/m²/day | Daily energy on a surface |
| Peak sun hours | h/day | Equivalent hours at 1,000 W/m² |
At STC reference, 1 kWh/m²/day ≈ 1 PSH before site derate.
CTA: Convert average W/m² in the Peak Sun Hours Calculator (irradiance fields).
Simple conversion #
Conclusion: Daily insolation ≈ (average W/m² ÷ 1000) × daylight hours (when average is over daylight).
Example: 417 W/m² average over 12 h → 417/1000 × 12 = 5.0 kWh/m²/day → ~5.0 PSH before derate.
Prefer plane-of-array (POA) data when tilt is fixed; GHI-only data needs transposition for accuracy (out of scope here—use OEM/meteo tools).
How data enters CalcPanel tools #
- Get PSH → Peak Sun Hours
- Size array → Solar Panel Sizing / How to Size a Commercial Solar Array
- Annual kWh → PV Energy Production with losses from Solar System Losses & Derating
Tilt effects: Solar Panel Tilt Angle Explained · Panel Tilt Calculator.
Common mistakes #
- Treating daylight hours as PSH.
- Using GHI as POA on steep roofs without adjustment.
- Double-counting soiling in both resource and loss %.
- Summer-only irradiance for winter autonomy.
Next steps #
- Peak Sun Hours Calculator on the Solar calculator hub.
- Solar Panel Sizing · PV Energy Production.
- Losses guide for derate bands.
Assumptions and disclaimer #
Average W/m² conversions are planning screens. Bankable designs need measured or licensed weather datasets and transposition models.
FAQ #
How do I use solar irradiance data for PV design?
Convert irradiance into daily insolation or peak sun hours, then enter PSH into array sizing and production calculators. Example: 417 W/m² × 12 h → 5.0 PSH before derate.
What is the difference between irradiance and peak sun hours?
Irradiance is instantaneous W/m². Peak sun hours are equivalent full-sun hours at 1,000 W/m² matching daily energy.
Can I enter W/m² in CalcPanel?
Yes—the Peak Sun Hours Calculator accepts average irradiance and daylight hours to set insolation/PSH.
Do I still need system losses?
Yes. Resource (PSH) and equipment/soiling losses are separate—see Solar System Losses & Derating.